CBHNN - 2251 ALUMIN-X
- MSDS: CBHNN
- Manufacturer: PRO CHEM INC
- Product Name: 2251 ALUMIN-X
- National Stock Number: 6850-00N068339
Product Identification
Product ID:2251 ALUMIN-X
MSDS Date:08/01/1993
FSC:6850
NIIN:00N068339
MSDS Number: CBHNN
Responsible Party
ALPHARETTA, GA 30201
US
Emergency Phone: 800-241-8180
Info Phone: 800-241-8180
Cage: GO127
Contractor
Telephone: 800-241-8180
Cage: GO127
Ingredients
HYDROFLUORIC ACID (SARA 302/313) (CERCLA)
CAS: 7664-39-3
RTECS: MW7875000
Fraction By Weight: 4.9%
OSHA PEL 3 PPM (F)
ACGIH TLV: 3 PPM (F), C
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
ETHANOL, 2-BUTOXY-; (2-BUTOXYETHANOL)
CAS: 111-76-2
RTECS: KJ8575000
Fraction By Weight: 2.5%
OSHA PEL 50 PPM, S
ACGIH TLV: 25 PPM, S
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:SEVERITY OF INJURY DEPENDS
LARGELY ON PRODUCT CONCENTRATION & DURATION OF EXPOSURE. IMMEDIATE
ACTION IS NECESSARY TO LIMIT SEVERITY OF INJURY. CAN CAUSE MINOR
IRRITATION TO SEVERE BURNS & TISSUE DAMAGE TO EXPOSED AREAS OF
BODY. CHRONIC:OVEREXPOSURE TO 2-BUTOXYETHANOL MAY CAUSE KIDNEY,
LIVER & RED(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:BLOOD CELL INJURY. MAY PENETRATE SKIN.
ANIMAL STUDIES CLEARLY DEMONSTRATED DOSE-RELATED ADVERSE EFFECTS ON
THE CNS, HEMATOPOIETIC TISSUES, BLOOD, KIDNEYS & LIVER, ASSOCIATED
W/ADMINISTRATION OF ETHYLENE GLYCOL MONOBUTYL ETHER (EGBE).
(EXTRACTED FROM DHHS (NIOSH) PUBLICATION NO.90-118) .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:EYES:FLUSH IMMED W/LG QTYS OF WATER FOR AT LST 15 MINS,
LIFTING EYELIDS. GET MED ATTN IMMED. SKIN:REMOVE CONTAM CLTHG &
WASH W/LG AMTS OF WATER FOR 15 MINS. GET MED ATTN IF NEC.
INHAL:MOVE PERS TO FRE SH AIR. IF BRTHG STOPS, ADMIN ARTF RESP. GET
MED ATTN IMMED. INGEST:GIVE LG AMTS OF WATER THEN SEVERAL GLASSES
OF MILK. DO NOT INDUCE VOMIT. GET MED ATTN IMMED.
Fire Fighting
Flash Point:NONE
Extinguishing Media:AS REQUIRED BY SURROUNDING FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:COULD REACT W/METALS TO GENERATE
FLAMMABLE HYDROGEN GAS.
Accidental Release
Spill Release Procedures:CONTAIN LARGE SPILLS & PUMP TO RECOVER. SMALL
SPILLS CAN BE MOPPED UP & RECOVERED. CONTAMINATED AREA SHOULD BE
NEUTRALIZED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE IN A COOL, DRY PLACE. KEEP
CONTAINER CLOSED WHEN NOT IN USE. KEEP OUT OF REACH OF CHILDREN.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . ONLY W/OUT ADEQUATE VENTILATION.
Ventilation:LOCAL EXHAUST.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . AS REQUIRED TO LIMIT SKIN CONTACT.
Work Hygienic Practices:WASH HANDS THOROUGHLY AFTER USE.
Supplemental Safety and Health
EYE PROT:& FULL LENGTH FACESHIELD .
Chemical Properties
Boiling Pt:B.P. Text:>212F,>100C
Spec Gravity:1.04 (H*2O=1)
Solubility in Water:100% SOLUBLE
Appearance and Odor:CLEAR LIQUID; CHARACTERISTIC ACID ODOR.
Stability
Stability Indicator/Materials to Avoid:YES
BASES, METALS, OXIDIZERS.
Stability Condition to Avoid:EXTREME TEMPERATURES.
Hazardous Decomposition Products:H*2, CO, CO*2.
Disposal
Waste Disposal Methods:DISPOSE OF I/A/W ALL LOCAL, STATE & FEDERAL
REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.